  1. while running pump or fill inlet hose with . oil from the pump end. Replace or re-configure pump to correct . rotation. Change inlet and pressure hose locations. See “PTO Troubleshooting” Repair or replace pump. Adjust relief valve to manufacturers specification. Remove, clean, and re-set to specification. Repair or replace pump. See “Oil ...

  2. PTO will not engage. (Hydraulic) Insufficient hydraulic pressure. Confirm 130-150 psi at “CL” port in solenoid manifold. If less, check hose connection to transmission. Misplacement of 90° orifice fitting (43T37385, silver color). Install orifice fitting in port on the bottom of the PTO housing. See PTO Installation and Owners Manual for ...

  3. oil from the pump end. Direct Mount Type– Re-configure pump to correct rotation. Remote Mount Type– Connect driveshaft to correct shaft as indicated by directional arrows. See “PTO Troubleshooting” Repair or replace pump. Remove, clean, and re-set to specification. Remove relief valve cartridge and clean load check area. Repair or ...

  4. PTO TrOubleshOOTing guide Condition Likely Cause Correction PTO will not engage. Connector is improperly positioned on rocker switch. Install connector with green wire on top (Pin 4) of switch. Shifter fork is not positioned in clutch ring. Remove and reinstall. Oil has been lost from motor/cylinder assembly. Replace motor/cylinder assembly

  5. Is your Muncie PTO TG series making noise, leaking or not engaging? View the troubleshooting guide to find the solution when your Muncie PTO is whining, clicking, rattleing, not engaging or leaking. Created Date

  6. Pro Gear presents Muncie CD10 Series PTO Parts & Service Manual to assist in identifying the parts for your Muncie Power Take Off unit. If you need any assistance identifying the correct Power Take Off unit for your truck and equipment, contact your Muncie replacement part specialists at Pro Gear and Transmission.

  7. 1 paź 2014 · 2011 GU813 MP7 with fuller 8ll & Muncie pto.... Pump engages normally, reservoir is full, no leaks. When engaged and recirculating it sounds normal, but when using the hydraulics to raise/lower box or cable in/out is sounds and surges like its starving for fluid....