Yahoo Poland Wyszukiwanie w Internecie

Search results

  1. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet (6096 mm), exclusive of shoulders, except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance clear to the sky.

  2. 503.2.1.1 - Single-lot single-family residential dwellings. Private on-site fire apparatus access roads serving a single-lot single-family residence may be reduced to a minimum width of not less than 15 feet (6,096 mm), exclusive of shoulders, when approved by the fire code official.

  3. The Fire Code is a component of the overall Los Angeles Municipal Code and is a combination of the California Fire Code and the Los Angeles amendments. The Adoption Ordinance shows which sections of the California Fire Code were adopted and any changes that were made.

  4. library.municode.com › ca › los_angeles_countyMunicode Library

    503.2 - Specifications. 503.2.1.1 - Single-lot single-family residential dwellings.

  5. library.municode.com › ca › los_angeles_countyMunicode Library

    Los Angeles County, California - Code of Ordinances; Title 32 - FIRE CODE; 503.1.1 - Buildings and facilities.

  6. Fire apparatus access roads shall be provided and maintained in accordance with Sections 503.1.1 through 503.1.3. Approved fire apparatus access roads shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the jurisdiction.

  7. Chapter 5, Fire Service Features, of the California Fire Code is adopted and/or amended to read as follows: 503.2.1.1 Dimensions. Sections 503.2.1 and 503.2.1.1 Table 503.2.1-A are added to the California Fire Code to read in their entirety as follows: 503.2.1 Private Roads Used for Fire Apparatus Access.

  1. Ludzie szukają również