See the FDOT Design Manual (FDM), Chapter 115, for additional information on the use of Standard Plans within FDOT Contract Plans. Subscribe to our FDOT Contact Management Subscription Service to receive the most current notices, bulletins, memoranda, and other important information.
- FDOT 2014 DESIGN STANDARDS of - Florida Department of Transportation
If sidewalk curb ramps are located where pedestrians must...
- FDOT 2014 DESIGN STANDARDS of - Florida Department of Transportation
The purpose of this Manual is to provide uniform minimum standards and criteria for the design, construction, and maintenance of all public streets, roads, highways, bridges, sidewalks, curbs and curb ramps, crosswalks (where feasible), bicycle facilities,
If sidewalk curb ramps are located where pedestrians must walk across the ramp, then provide feasible cross slope shall be provided. Ramp slopes are not required to exceed 15’ in length.
Use the curb ramp options as follows: • Curb Ramps CR-A, CR-B & CR-C are for use where ramp and landing depths are not restricted. • Curb Ramps CR-D, CR-E, CR-F, CR-G and CR-H are for linear pedestrian traffic. • Curb Ramps CR-K and CR-L are for use where ramp and landing depths are restricted.
3. Curb Ramp Alpha-Identification: curb transition or to the extent that no remaining section is less than 5 feet long. B. Remove any existing curb, curb and gutter, or sidewalk to the nearest joint beyond the A. Refer to Index 522-001 for concrete thickness and sidewalk details. 2. Curb, Curb and Gutter and/or Sidewalk: with Index 522-001.
Ramp slopes are not required to exceed 15 feet in length. C. Install ramp slopes along a single linear plane (i.e. no warps or varying slope). B. Landings must have cross-slopes less than or equal to 0.02 in any direction.
A. Refer to Index 522-001 for concrete thickness and sidewalk details. 2. Curb, Curb and Gutter and/or Sidewalk: with Index 522-001. No joints are permitted within the ramp portion of the Curb Ramp. D. Joints permitted at the location of Slope Breaks. Otherwise locate joints in accordance Ramp slopes are not required to exceed 15 feet in length.