  1. 5 maj 2020 · equal pressure both sides of the gauges. by craftsman » Tue May 05, 2020 1:37 pm. I'm just starting to diagnose a 2006 Hyundai Elantra, but could use a little help. The clutch engages and spins the compressor. The gauges were showing equal on both the high and low sides. They were at 35 each, then I added a little r134a and they both said 40.

  2. 6 wrz 2016 · It made no difference in vent temp, and the gauges showed the same readings as before. High side is about 100, Low side is about 40. So it seems like the refrigerant is evaporating completely before it reaches the driver's side of the evaporator - due to the lack of sufficient pressure differential between High and Low sides.

  3. I borrowed the gauge kit from AutoZone and got the following readings with the AC running and the compressor clutch engaged: low side pressure around 90psi, high side pressure around 150psi. Based on ambient temperature around 95F I think that high side pressure is a bit low. Pressures with the engine off were around 105 on both sides.

  4. 18 lip 2021 · The rear temp control is via a roof mounted blend door NOT a dedicated evaporator and heater core. @2000 rpm, doors open fan on high; low 37-40, high 147-150, using a Thermopen duct temp 63.8°on both sides, ambient 83°, humidity 80% and cloudy. Driving down the road @2000 rpm both sides temps hit upper 40°'s.

  5. 7 lip 2021 · Both low side and high side pressures are higher than normal. High side will approach 300 psi possibly more. The low side was maybe 60 perecent higher than it should be. Unit is not over charged in fact it’s undercharged by about 60 percent. Unit has been pulled down and charged from a vacuum. I have not veirified this but dealer tells me ...

  6. 25 maj 2020 · The first one had pressures on each gauge the same (60/60). The Saab was yet another weird one as the gauges both showed low (about 10psi on each gauge) on hookup so I assumed that I should add refrigerant. With the engine running and system maxed out via the controls, I got a reading of 30 low/50 high. I was thinking that the high side gauge ...

  7. 4 cze 2024 · Re: High pressure on high side after AC rebuild Post by SLOWoody » Tue Jun 04, 2024 11:17 pm The ambient temp reading is from a thermometer on my garage door opener (69F) and the readings from my condenser output was done using an IR (non-contact) thermometer.

  8. Ac system will not take full charge. by John861214 » Wed Jul 05, 2017 4:42 pm. Hi I'm working on a 02 Dodge Durango with front and rear ac the rear doesn't blow cold the front is cool but not cold as it should be I just replaced compressor expansion valve and dryer under hood vacuum down the system waited a hour it held started to charge with ...

  9. 4 lip 2018 · Pressures run higher on 134a conversions. Your current high side pressure is very conservative. We use a P:T ratio to describe condenser performance, with P being the high side pressure, and T being ambient temperature. It is not uncommon to see a P:T over 3:1 on a 134a conversion at full load.

  10. 30 wrz 2018 · Everything was new except the compressor. Currently the pressures are reading 60 on the low side and 120 on the high side. Air is blowing cold but the compressor is continuously on. I’m trying to figure out what I did wrong or if the compressor itself is bad. I should note that I forgot to add the 40 ml of oil to the condenser before ...