  1. 12 lis 2005 · Ballpeen, Your motor is one of the following types: Constant Torque 2 Speeds. The HP shown on the nameplate are in the ratio of ½, if so, connect: LOW SPEED ( Lower HP) Line 1 to motor Terminal 1. Line 2 to motor terminal 2. Line 3 to motor terminal 3. Leave motor terminals 4,5 & 6 open and insulated from each other.

  2. 18 paź 2012 · 2) If you are only doing this for soft starting, a VFD is a waste and a risk. The risk is from adding complexity unnecessarily. The waste is that you will consume more energy because of the inherent losses in the VFD. The losses aren't much, but they are unnecessary if there is an alternative. You ALREADY have a 2 speed motor, so you have an ...

  3. 23 maj 2023 · The motor connections (and thus the types of controllers) for two speed starters are exemplified by the schematic diagrams shown in Table 16.22. Note that consequent pole two-speed controllers involve a 5-pole and a 3-pole starter, while separate winding controllers have two 3-pole starters. Verify the type of motor before ordering.

  4. 7 kwi 2005 · For two motors pick a 3600 rpm for high speed and 900rpm for low speed. Both should be reasonably available in single phase and reasonably cheap. The 2 pole motor will require 4 times the hp of the 8 pole motor. Make sure you pick a single phase type that gives you the starting and accel torque you need.

  5. 16 wrz 2013 · RPM = (120*F/Poles) - Slip. When the speed ratio is 2 you could use the Dahlander conection, this one is very usefull when you need two speeds with only one winding. Like Lionel sayds, all motor parameters of each winding depends of machine design.I will add the main parameters for winding design : Turns, Span, Wires on hand, Connection type (D ...

  6. 6 wrz 2005 · A 5kW motor at 1/2 speed was using .5 x .5 x .5, or 1/8th of the motor power compared to full speed operation, so you were using only .625kW. What is happening now is that your new 5kW motor is turning at full speed and providing the same flow. Technically you may have been able o do that with a smaller motor, i.e. .75kW depending on the pump ...

  7. 30 sie 2022 · In general, single-phase motors are designed for single speed. For 2-speeds, there may be 3-4 terminal for different voltages or speeds. High Speed Max. Flow Rate: 340L per min./ 90 GPM. Low Speed Max. Flow Rate: 159L per min./ 42 GPM. High Speed Max. Head Lift: 49 ft/ 15 m. Low Speed Max.

  8. 21 mar 2007 · You can find three kinds of two speed motors: 1. Dahlander conected, very well explained above.With only one winding making external conection you can obtain one speed or the double due to a P change, in this motors High Speed/Low Speed = 2. 2.

  9. 3 lis 2005 · 4-pole does a little worse on power factor and a little worse in core losses. 2-pole does a little worse in friction and windage losses. If you start looking at efficiency, don't ever overlook the driven load which usually is where most of the losses are. (motors typically above 95% efficiency, pumps often 60% efficiency).

  10. 2 kwi 2023 · RE: 2 Speed 2 Wind Motor Won't Cold Start After 9 Months in Full Operation edison123 (Electrical) 12 May 23 01:57 Since the 'new' motor runs fine for a few days/months and then starts to crawl and it was built with crappy re-used parts, I think the 'designer' put the original rotor bars too close to the crawling zone and a few rotor bars failed over time thereby putting it in the crawl zone.