27 sie 2015 · General guidelines says most cables will support 115k baud, using x-on/x-off protocol (stop start is data on tx/rx lines) are limited to 30M, or about 100' with shielded cable. UTP cables using this same protocol setup are limited to about half the speed, so maybe 56k.
29 mar 2001 · Maximum Cable Length. As we have seen, the cable-length specification once included in the RS-232 standard has been replaced by a maximum load-capacitance specification of 2500pF. To determine the total length of cable allowed, one must determine the total line capacitance.
4 mar 2021 · Using typical underwater cables, allowable combinations of cable length and baud rate for Sea-Bird instruments communicating with RS-232 are shown below: Maximum Cable Length (meters) Maximum Baud Rate*
RS232 conveys data over a simple unterminated, multiconductor cable at rates up to 20kB. The RS232 standard specifies the electrical characteristics and connector for an all encompassing point-to-point modem interface.
This document gives an overview on the RS-232 standard, provides explanations of key electrical and timing specifications of RS-232 transceivers, and includes a selection guide to help choose the correct RS-232 for a specific application.
Maximum cable lengths. Cable length is one of the most discussed items in RS232 world. The standard has a clear answer, the maximum cable length is 50 feet, or the cable length equal to a capacitance of 2500 pF. The latter rule is often forgotten.
Appearance. This article is about the RS-232, standard. For RS-232 variants, including the common 9-pin connector, see serial port. A DB-25 connector as described in the RS-232 standard. Data circuit-terminating equipment (DCE) and data terminal equipment (DTE) network.