Yahoo Poland Wyszukiwanie w Internecie

Search results

  1. To retrieve Audits from a safe lock to the LA GARD Software client, refer to Section 5.4 “Retrieve Audits” later in this document. Further details concerning Audits can be found in section 3.17 “Time/Date Rules in LA GARD 700 Series Locks”. dormakaba USA Inc. System User Guide 7040.0821 | 35...

  2. When a lock is reset, the Master Combination is reverted to the default (1-2-3-4-5-6-7-8) and all Managers/Users are deleted. All System and lock settings will be reset to their defaults. All locks will be uninstalled and unpaired to any Keypad. dormakaba USA Inc. System User Guide 7040.0321 | 27...

  3. If locks are already paired to one system, they can be reset, utilizing the LA GARD 700 Series Reset Box (704065) or the lock can be Uninstalled (#23) from the old keypad and installed to the new keypad.

  4. 1. Disconnect the safe lock from all power sources. The safe lock should also be disconnected from any Keypad or Multiplexer prior to connecting the Reset Box. 2. Insert batteries into the Reset Box. 3. Connect the Reset Box to the Safe Lock BAT port. 4. The LED will illuminate and then stop when the reset is complete. DO NOT

  5. Reset the lock SMRC If the Super Master Reset Code has been activated because it was changed before the Manager code was changed, it can be used to reset the lock. After reset, the Manager code defaults to 1-2-3-4-5-6, the user code is deleted, and Super Master Reset Code remains the same. • Press and hold 0 for 3 seconds A second set of

  6. Security – the ultimate in state-of-the-art electronic safe locks designed to support the ever-changing needs of today’s world; Efficiency – lower total cost of ownership, fewer battery changes, ease of use, simplified inventory management; Confidence – from a name you know and trust

  7. Disconnect the Reset Box from the Safe Lock. Once successfully reset, the Master User Combination will be reset to 12345678. Reconnect the Safe Lock to the system. Note: If the Reset Box LED does not turn on, disconnect the Reset Box, and repeat steps 1 and 2.