CLOSED SUCTION FEATURES. Low durometer catheter and rounded atraumatic tip to minimize tracheal trauma. Elbow and “Y” configurations for standard and high-frequency ventilation. Available in 5, 6, 7, 8, 10 & 12 French sizes. Reusable up to 24 hours.
- BALLARD CLOSED SUCTION SYSTEM FOR ADULTS - AirLife
Control Depth Suction (For catheters with numerical markings...
- BALLARD™ Closed Suction Catheter System, Double Swivel Elbow
Depth markings for easy and proper depth suctioning. “Soft”...
- BALLARD™ Closed Suction Catheter System for Neonates ... - AirLife
Remove secretions from the airway while maintaining...
- Fig. 1 CLOSED SUCTION SYSTEM FOR NEONATES/PEDIATRICS (Fig. 4)
1. Align any printed depth number on the catheter with the...
- BALLARD™ Closed Suction Catheter System, T-Piece - AirLife
BALLARD™ Closed Suction Catheter System, T-Piece. Latex...
- BALLARD CLOSED SUCTION SYSTEM FOR ADULTS - AirLife
Control Depth Suction (For catheters with numerical markings only): 1. Align any printed depth number on the catheter with the similar number printed on the endotracheal tube, or observe the printed number on the endotracheal tube closest to the endotracheal tube adaptor. 2. Add 6 cm to this number. 3.
Depth markings for easy and proper depth suctioning. “Soft” low durometer catheter to minimize tracheal trauma. Tactile sleeve for catheter advancement. Integrated MDI port options. One-way cleaning port. Locking thumb port. Made of PVC. WET PAK configurations include 5ml saline bullets. Brand: BALLARD™.
Remove secretions from the airway while maintaining ventilation and oxygen therapy throughout the suctioning procedure. Reusable up to 24 hours. Number and color-coded markings for easy and proper depth suctioning. “Soft” low durometer catheter to minimize tracheal trauma. Tactile sleeve for catheter advancement.
1. Align any printed depth number on the catheter with the same number printed on the endotracheal tube. 2. Catheter tip will be within 0.5 cm to 1 cm of the end of the endotracheal tube. Method 2 1. Observe the printed depth number on the endotracheal tube closest to the end of the endotracheal tube adapter. 2. Add 5 to this number. 3.
BALLARD™ Closed Suction Catheter System, T-Piece. Latex Free. Single Use. Sterile. Select Items are Part of AirLife Secure! Powerful tool in your fight against VAEs. Designed to remove secretions from the airway while maintaining ventilation and oxygen therapy throughout the suctioning procedure.
• Attach a new BALLARD* Closed Suction System and advance the catheter until the catheter tip is just barely visible beyond the tip of the tracheostomy tube .